Commercial · Solutions
Building Lifting & Tilt Correction
Lift and realign tilted buildings to restore verticality and structural performance.
Engineering overview
Controlled Grouting Lifting & Building Tilt Correction
Using non-disruptive, controlled lifting and tilt-correction technology, a specialty composite material is precisely injected beneath the building foundation.
Through staged shallow and deep treatment, the grout generates an upward lifting force during injection. Combined with an intelligent monitoring system, it achieves millimeter-level, precisely controlled lifting and tilt correction, gradually correcting building tilt, restoring verticality and structural load balance, while strengthening the soil to form a stable composite foundation for tilt correction, realignment, and long-term settlement control.
What to assess
The information that shapes the repair path
Review movement history, ground and drainage conditions, structural loads, access constraints and acceptance criteria. Visible symptoms alone do not determine the suitable intervention.
01
Movement history and visible symptoms
02
Ground and drainage conditions
03
Structural loads and tolerances
04
Access and operating constraints
05
Monitoring and acceptance criteria
06
Long-term asset performance
Staged injection · real-time measurement
Our approach
Hengxiang Hongye Critical Remediation Steps
Through our non-destructive and controllable patented technology, the weak soil layer of the holding layer is consolidated as a whole, and the consolidated and reinforced foundation soil forms a composite foundation, whose bearing capacity value can reach nearly three times of the original bearing capacity, and well support the upper load.
- 01Drilling
Bore holes in the affected area with a diameter of 6–10 mm.
- 02Injection
Inject a specialized inorganic material.
- 03Solidification
The material rapidly solidifies with soil, filling voids and stabilizing the ground.
- 04Re-balancing
Lift and reinforce the foundation until re-leveling is achieved.
Start with the condition
Not sure which engineering path fits your asset?
Share photographs, drawings or monitoring information. The team can review the condition and recommend a practical next step.
Industry context
Related Sectors
Connected conditions
Related Challenges
Engineering response
Related Solutions
Connected evidence
Continue into relevant solutions and work
01Manufacturing · Active facility
Chery New Energy Facility Settlement Lifting
02Steel plant · Equipment foundation
HBIS Gas Cabinet Foundation Correction
03Battery plant · Ground improvement
CATL Factory Settlement Treatment
Technical resources
Supporting information for the next decision
01Industry brief · 7 min
Industrial Foundation Repair Without Extended Shutdown
02Engineering insight · 6 min
When Can an Equipment Base Be Re-Leveled?
03Checklist · 5 min
